Viewing Issue Advanced Details
| ID | Category [?] | Severity [?] | Reproducibility | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 08682 | DIP/Input | Minor | Always | Jun 23, 2023, 22:42 | Jun 25, 2023, 16:18 |
| Tester | Balthier | View Status | Public | Platform | MAME (Official Binary) |
| Assigned To | Resolution | Open | OS | Windows 10/11 (64-bit) | |
| Status [?] | Acknowledged | Driver | |||
| Version | 0.255 | Fixed in Version | Build | 64-bit | |
| Fixed in Git Commit | Github Pull Request # | ||||
| Summary | 08682: bubbletr, bubbletrj, gollygho: Diorama Test shows a constant increasing SCI ERROR | ||||
| Description | The diorama test in service mode for these games has a rapid increasing SCI ERROR. The count resets each time you leave and reenter service mode. | ||||
| Steps To Reproduce |
1. Run any of the games affected. 2. Press F2, then 9 key twice. |
||||
| Additional Information | |||||
| Github Commit | |||||
| Flags | |||||
| Regression Version | |||||
| Affected Sets / Systems | bubbletr, bubbletrj, gollygho | ||||
|
Attached Files
|
|||||
Relationships
| There are no relationship linked to this issue. |
Notes
1
|
No.21588
AJR Developer
Jun 25, 2023, 16:18
|
This bug is due to missing SCI (UART) emulation in the M37450 microcontroller (which is not even configured correctly at the moment). |
|---|