Viewing Issue Advanced Details
ID | Category [?] | Severity [?] | Reproducibility | Date Submitted | Last Update |
---|---|---|---|---|---|
08682 | DIP/Input | Minor | Always | Jun 23, 2023, 22:42 | Jun 25, 2023, 16:18 |
Tester | Balthier | View Status | Public | Platform | MAME (Official Binary) |
Assigned To | Resolution | Open | OS | Windows 10/11 (64-bit) | |
Status [?] | Acknowledged | Driver | |||
Version | 0.255 | Fixed in Version | Build | 64-bit | |
Fixed in Git Commit | Github Pull Request # | ||||
Summary | 08682: bubbletr, bubbletrj, gollygho: Diorama Test shows a constant increasing SCI ERROR | ||||
Description | The diorama test in service mode for these games has a rapid increasing SCI ERROR. The count resets each time you leave and reenter service mode. | ||||
Steps To Reproduce |
1. Run any of the games affected. 2. Press F2, then 9 key twice. |
||||
Additional Information | |||||
Github Commit | |||||
Flags | |||||
Regression Version | |||||
Affected Sets / Systems | bubbletr, bubbletrj, gollygho | ||||
Attached Files
|
sci_error.png (8,078 bytes) Jun 23, 2023, 22:42 Uploaded by Balthier
| ||||
Relationships
There are no relationship linked to this issue. |
Notes
1
No.21588
AJR Developer
Jun 25, 2023, 16:18
|
This bug is due to missing SCI (UART) emulation in the M37450 microcontroller (which is not even configured correctly at the moment). |
---|