Viewing Issue Advanced Details
| ID | Category [?] | Severity [?] | Reproducibility | Date Submitted | Last Update |
|---|---|---|---|---|---|
| 01447 | DIP/Input | Major | Have not tried | Feb 29, 2008, 04:22 | Oct 12, 2008, 01:59 |
| Tester | -Misc Reporters- | View Status | Public | Platform | |
| Assigned To | R. Belmont | Resolution | Fixed | OS | |
| Status [?] | Resolved | Driver | |||
| Version | 0.123u3 | Fixed in Version | 0.127u8 | Build | |
| Fixed in Git Commit | Github Pull Request # | ||||
| Summary | 01447: propcycl: Analog input roll over problem. | ||||
| Description |
The propcycle controls work fine for me except when they reach full right, they suddenly switch to hard left, and the same with up and down. I see the calibration screen alright. It appears to have only one function, adding a bias recorded by pressing the service button to the control inputs. That part works fine, but I think what I'm looking for is some way to limit the input range. If I move my mouse fully left, I get a base/value reading of 03F8/0200, as I slowly move the mouse right, it slowly drops to 0004/FE0C but at full right, it suddenly jumps to hard left 03FC/0204. |
||||
| Steps To Reproduce | |||||
| Additional Information | Posted by YoungSon | ||||
| Github Commit | |||||
| Flags | |||||
| Regression Version | |||||
| Affected Sets / Systems | propcycl | ||||
|
Attached Files
|
|||||
Relationships
| There are no relationship linked to this issue. |
Notes